气体增压泵故障及其处理方法

气体增压泵故障及其处理方法1泵不工作:

1 pump does not work:

a.检查驱动气源是否开启,驱动压力是否满足要求;

A. check the drive source is turned on, the driving pressure whether meet the requirements;

正常空气增压泵的进气压力要求3-8bar,泵长期不工作,应先向驱动气口内喷少量润滑油,最好为硅油,然后驱动气压尽量调高,待泵正常运行几分钟后,再装气压调至所需压力,新泵装配过程中,都会在换向阀内涂一层润滑脂,长期不用时,润滑脂会凝固。

The normal air intake pressure booster pump for 3-8bar, the pump does not work, should first to drive air outlet in spray a small amount of lubricating oil, preferably silicone oil, then driven pressure to increase, to pump the normal operation after a few minutes, and then loaded pressure adjusted to the required pressure, the new pump assembly process, will be in the reversing valve coated with a layer of grease, not a long time, will be solidified lubricating grease.

c. 检查换向阀气路是否畅通;

C. check valve gas path is smooth;

2.泵动作突然加快,驱动活塞不到头就换向:

2 pump action suddenly accelerate, driving the piston does not end on reversing:

a. 撞针漏气。

A. striker leakage.

长期使用,尤其无油润滑的情况下,可能会出面撞针前后腔串气,致使撞针密封不好,换向阀工作不正常,泵频率加快。

The long-term use, especially non oil lubricating condition, may step in to a cavity mixes up, resulting in the firing pin seal is not good, the reversing valve is not working properly, the pump speed.